Thermocouple Connector Plugs & Sockets (ANSI/IEC Standard)

In precision temperature measurement, a bad connection equals bad data. Hongtai Thermocouple Connectors are engineered to maintain the integrity of your sensor signal from the probe tip to the instrument panel. Unlike generic electrical plugs, our connectors use compensated thermocouple alloys (e.g., Chromel/Alumel pins for Type K) to prevent “cold junction” errors at the connection point.

We offer a complete range of Standard thermocouple connector (Round Pin) and Miniature thermocouple plug (Flat Pin) formats. All housings are strictly color-coded to ANSI (USA) or IEC (Europe) standards, providing a “fool-proof” visual guide that prevents cross-wiring errors in complex instrumentation panels.

Thermocouple Connectors (2)

Key Technical Features & Benefits

  • Alloy-Matched Pins: The male pins and female sockets are made from the specific thermocouple alloys (not just plated copper). This ensures zero thermal EMF generation at the plug.

  • Color Coded Safety:

    • ANSI (USA): Yellow (Type K), Black (Type J), Blue (Type T), Purple (Type E).

    • IEC (Europe): Green (Type K), Black (Type J), Brown (Type T), Violet (Type E).

  • High Temp Options: Standard thermoplastic bodies are rated to 200°C. For vacuum furnaces, we offer High temp ceramic connector bodies rated to 650°C.

  • Quick Wiring: “Sandwich” construction allows for rapid wire termination without loose screws falling out.

  • Panel Mounting: Snap-in panel sockets available for building custom control boxes.

Technical Specifications

Parameter Standard Connector Miniature Connector Ceramic Connector
Pin Shape Round Pins (Solid/Hollow) Flat Pins (Blade) Round Pins
Body Material Glass-Filled Nylon (Thermoplastic) Glass-Filled Nylon High Alumina Ceramic
Max Temperature 200°C (400°F) 200°C (400°F) 650°C (1200°F)
Calibration K, J, T, E, N, R/S, B, U K, J, T, E, N K, J, E
Wire Size Up to 14 AWG (Stranded) Up to 20 AWG Up to 14 AWG
Color Code ANSI or IEC ANSI or IEC White (Dot Coded)

Application Scenarios

  1. Instrument Panels: Panel-mount sockets allow operators to quickly plug in handheld probes.

  2. Laboratories: Quick-disconnect setups for R&D test rigs.

  3. Industrial Ovens: Ceramic connectors used inside the heated zone to extend sensor wires.

  4. Plastics Machinery: Connecting mold thermocouples to the mainframe.

Visual Guide: Mini vs. Standard

  • Miniature (Mini): Used on handheld thermometers and fine-wire probes. Pins are flat blades.

  • Standard: Used on heavy-duty industrial probes and extension cables. Pins are round solid rods.

FAQ

Q: Can I use a Type K plug with a Type J wire?

A: No. Mixing alloys will create a “parasitic junction” causing massive temperature errors (up to 50°C offset). You must match Yellow Plug (K) to Yellow Wire (K).

Q: Are the pins solid or hollow?

A: Our Standard connectors feature Solid Pins for durability. Cheaper competitors use hollow tubes which can crush under screw pressure.

Need wire? See our Thermocouple Extension Cables.

View Thermocouple Color Code Chart.

Get Factory Price Quote

Contact Form Demo

You May Also Like

FAQ

Q1 : Why choose us ?

A: Our product has low MOQ , high quality which meets standard . We provide high level service and trade assurance order

Q2: Can you supply customize service?

A: Yes, we can supply OEM & ODM service according to your drawings or requirement.

Q3: How long can i get the order?

A: The delivery time depends on order quantity,Normally can be ready within 7-15 working days

Q4. How can you guarantee quality?

A. We strictly follow the aoreed product parameters and material performancenn.Before delivery,we willtake photos and ask you to verify the productinformation. lf you have any other questions,please feel free to contact us.