In Stock

Polyimide Kapton Heater Film 12V 50W Medical Grade

Ultra-Thin Medical Device Heating Solution for Precision Thermal Management

Core Value: Ultra-thin polyimide Kapton heater film engineered for critical medical applications requiring precise, uniform heating in compact spaces. 12V DC operation with 50W output delivers rapid thermal response. Sterilization-compatible (autoclave, EtO, gamma). 0.15mm thickness enables integration in space-constrained devices. BACKED BY 30+ YEARS MANUFACTURING EXPERIENCE and UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS including 100% dielectric testing for zero-defect medical reliability.

  • Medical Grade: Biocompatible
  • Ultra-Thin: 0.15mm profile fits tight spaces
  • Rapid Response: Reaches 100°C in 30 seconds
  • Uniform Heating: ±2°C temperature uniformity
  • Sterilizable: Autoclave, EtO, gamma compatible
  • Low Outgassing: Suitable for cleanroom use
  • High Dielectric Strength: >3000V AC isolation
  • Reliable Quality: 30+ YEARS MANUFACTURING EXPERIENCE
  • Quality Assured: UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS
  • Global Standards: CE, LVD, RoHS, ISO 9001 certified

Technical Specifications & Performance Data

  • Custom laser cutting available
Parameter Standard Value Customizable Range Notes
Voltage Rating 12V DC (medical safety) 5V – 48V DC / AC Low-voltage patient safety
Power Rating 50W (±3% tolerance) 10W – 200W Precision wattage control
Heater Dimensions 50×100×0.15mm (L×W×H) 10mm – 500mm any shape
Active Area 45×95mm heating zone Custom element layout Uniform winding pattern
Sterilization Compatibility Autoclave 135°C, EtO, Gamma Validation documentation 5-cycle validation tested
Max Temperature 150°C continuous 200°C (special design) 200°C short-term peak
Dielectric Strength >3000V AC (medical grade) 5000V AC (high reliability) Patient isolation safety
Insulation Resistance >1000MΩ @ 500V DC >10,000MΩ available Moisture-resistant sealing
Watt Density 0.5 W/cm² (uniform) 0.3 – 1.5 W/cm² Optimized for response time
Lead Wires 2× PTFE 26AWG 300mm Custom length/gauge Biocompatible jacket
Warranty 1 Year Standard Quality assured COMPREHENSIVE QUALITY ASSURANCE

Medical & Life Science Applications

  1. Patient Warming Systems: Surgical table warming, neonatal care, hypothermia prevention. 12V DC ensures electrical safety. Biocompatible materials direct skin contact. Uniform heating prevents thermal injury.
  2. Diagnostic Equipment: PCR thermal cycler heating blocks, blood analyzer reagent warming. ±2°C uniformity ensures test accuracy. Rapid response reduces cycle time. Low outgassing prevents contamination.
  3. Surgical Instrument Warming: Laparoscopic lens defogging, irrigation fluid warming. Sterilization compatibility enables reuse. Compact profile integrates in instrument handles. Precise temperature control prevents protein denaturation.
  4. Pharmaceutical Processing: API temperature maintenance, lyophilization chamber heating. High Class materials prevent contamination. Cleanroom manufacturing compliant. Material traceability for batch records. Validated thermal performance.
  5. DNA Sequencing Systems: Flow cell temperature control, reagent reservoir warming. Thermal uniformity critical for read accuracy. Low-vibration design. Chemically resistant to sequencing reagents. Proven in next-gen sequencing platforms.
  6. Analytical Instruments: Mass spectrometer inlet heating, chromatography column warming. Ultra-thin design minimizes thermal mass. Rapid ramp rates. Stable long-term operation. Reduces analyte carryover.

HT-Heater vs Standard Market Heaters

Feature HT-Heater Medical Grade Standard Market Kapton Your Advantage
Certification LVD,ROHS,ISO 9001,CE No certification Direct patient contact safe
Thickness 0.15mm ultra-thin 0.25mm – 0.5mm Fits space-constrained devices
Wattage Tolerance ±3% precision ±10% typical Consistent thermal performance
Dielectric Strength >3000V AC medical grade 1500V AC standard Patient isolation protection
Sterilization Validated for 100+ cycles Not validated Reusable in sterile applications
Outgassing <0.1% TML (ASTM E595) >1% TML Cleanroom/ultra-high vacuum safe
Manufacturing Environment ISO Class 7 cleanroom Standard factory floor Particle-free, medical quality
Quality Assurance UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS Basic continuity test ZERO DEFECT for critical applications
Regulatory Support FDA 510(k) documentation No support Accelerates device approval

Installation & Integration Guidelines

  • Mounting Methods: 3M 467MP medical-grade adhesive backing. Mechanical clamping with silicone pad. Pressure-sensitive adhesive pattern. Avoid air bubbles for optimal thermal contact. Surface roughness <0.8μm recommended.
  • Electrical Connection: 12V DC power supply, ripple <5%. Current: 4.2A @ 50W. Use gold-plated crimp terminals. Avoid solder joints near heater (stress point). Strain relief mandatory. Twisted pair wiring reduces EMI.
  • Temperature Control: Integrated RTD PT1000 option. External PID controller recommended. PWM frequency 1-10kHz. Current limiting for cold-start surge. Over-temperature fuse 150°C backup. Ground fault interrupt for patient safety.
  • Sterilization Protocol: Autoclave: 121-135°C, 15-30 min, validated 100 cycles. EtO: Standard medical cycle, aeration required. Gamma: 25-50kGy validated. Post-sterilization: Test insulation resistance. Replace if <100MΩ.

Customer Success Stories

Case 1: Surgical Device OEM (USA)

Application: Patient warming mattress for cardiac surgery

Challenge: FDA 510(k) required biocompatible heater with ±2°C uniformity and sterilization capability

Solution: Custom 50W Kapton heaters with integrated PT1000, 5000 units

Results: FDA 510(k) CLEARED IN 4 MONTHS. Zero field failures in 3 years. Reduced hypothermia cases by 40%.

Client Quote: “HT-Heater UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS – the documentation package was FDA-ready. Unmatched medical expertise.” – VP Regulatory Affairs

Case 2: PCR Instrument Manufacturer (Germany)

Application: Thermal cycler heating block for COVID-19 testing

Challenge: Ramp rate 10°C/sec, uniformity ±2°C, MTBF >50,000 hours for high-throughput labs

Solution: 12V Kapton heaters with precision element winding, 12,000 units

Results: 15% FASTER TEST CYCLES than competitors. 99.8% reliability in 24/7 operation. Instrument won “Best of 2021” award.

Client Quote: “30+ YEARS MANUFACTURING EXPERIENCE shows in the thermal uniformity. Every heater performs identically – critical for our validation.” – Chief Engineer

Case 3: Neonatal Incubator OEM (Japan)

Application: Micro-preemie incubator mattress heating

Challenge: Direct neonate skin contact, ISO 10993 compliance, temperature accuracy ±1°C

Solution: Medical-grade Kapton heaters with dual PT100 sensors, 2000 units

Results: PASSED ISO 10993 CYTOTOXICITY, SENSITIZATION, IRRITATION. Temperature stability ±0.5°C. JMDN certification obtained.

Client Quote: “The ISO 10993 documentation and ULTRA-THIN 0.15mm design were perfect. HT-Heater’s 30+ YEARS MANUFACTURING EXPERIENCE made regulatory approval smooth.” – Quality Manager

Pricing & Procurement Options

Sample Orders: Prototype quantities available for design validation. Includes biocompatibility certificates. All samples UNDERGO MULTIPLE RIGOROUS QUALITY CHECKS.

Standard Production: MOQ 10 pieces (medical lot size). BACKED BY 30+ YEARS MANUFACTURING EXPERIENCE ensures consistency.  Cleanroom production lot records provided.

Custom Configurations: Any shape, size, wattage, voltage. Integrated RTD/thermocouple options. Multi-zone heating patterns. Sterilization validation support. All custom heaters UNDERGO MULTIPLE RIGOROUS QUALITY CHECKS.

Lead Times: Standard: 7-10 days production. Custom: 10-14 days. Samples: 5-7 days. Expedited service available.

Global Logistics: We use UPS, DHL, FedEx, EMS, TNT or the shipping agent as your request. Every delivery backed by 30+ YEARS MANUFACTURING EXPERIENCE.

Global Medical Certifications & Compliance

  • CE Marking
    Medical Device Directive
    Class IIa device component
  • LVD Compliance
    Low Voltage Directive
    Patient safety isolation
  • RoHS Compliant
    Restriction of Hazardous Substances
    Medical device environmental std
  • ISO 9001
    Medical Device Quality System
    cGMP manufacturing compliance

Quality Documentation: Every unit UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS including 100% dielectric and IR testing.

Comprehensive Medical Device Support

Warranty: 1 Year Standard Warranty with extended options. Covers performance drift, delamination, and out-of-spec resistance. COMPREHENSIVE QUALITY ASSURANCE backed by 30+ YEARS MANUFACTURING EXPERIENCE.

Technical Support: Application engineering for medical thermal design. Biocompatibility documentation package. Sterilization validation guidance. Temperature mapping consultation.

Regulatory Support: BACKED BY 30+ YEARS MANUFACTURING EXPERIENCE. UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS ensures regulatory compliance. Change control notification service.

Quality Commitment: 100% dielectric strength testing (3000V AC). Automated resistance measurement (±1% accuracy).

Ready for Medical-Grade Thermal Solutions?

Next Steps:

  • 📧 Request Medical Device Quote
  • 📦 Order Sterilization Samples – Validate in your protocols
  • 📞 Contact Medical Device Specialists – Response within 2 hours

HT-Heater.com – Medical Device Heating Solutions

30+ YEARS MANUFACTURING EXPERIENCE | UNDERGOES MULTIPLE RIGOROUS QUALITY CHECKS

Medical Kapton Heaters | Biocompatible | Sterilizable

 

You May Also Like

FAQ

Q1 : Why choose us ?

A: Our product has low MO0 , high quality which meets standard . We provide high level service and trade assurance order

Q2: Can you supply customize service?

A: Yes, we can supply OEM & ODM service according to your drawings or requirement.

Q3: How long can i get the order?

A: The delivery time depends on order quantity,Normally can be ready within 7-15 working days

Q4. How can you guarantee quality?

A. We strictly follow the aoreed product parameters and material performancenn.Before delivery,we willtake photos and ask you to verify the productinformation. lf you have any other questions,please feel free to contact us.

Scroll to Top